What was found
GREEN SYSTEM HYD TEMP HI LIGHT ON. BLED & SERVICED HYD SYS IAW A300 MM CH 12-12-00. SYS OPS CHECK GOOD & NO TEMP LITE WITH ENG. RUN.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GREEN SYSTEM HYD TEMP HI LIGHT ON. BLED & SERVICED HYD SYS IAW A300 MM CH 12-12-00. SYS OPS CHECK GOOD & NO TEMP LITE WITH ENG. RUN.