As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LOST FLUID IN GREEN HYD SYS LANDING GEAR MANUALLY EXTENDED. REMOVED AND REPLACED NR 2 ENG GREEN SYS HYD PUMP AS REQ, LEAK & OPS CHECK GOOD. SERVICED GREEN SYSTEM AS REQ IAW A300 MM 29-11-32. RESTORED LANDING GEAR ACT SYS TO NORMAL IAW A300 MM 32-30-00.