Service difficulty report · Duct · Airbus A319112

Difficulty date
February 20, 2008
Submitted
February 25, 2008
Operation
Air carrier
Aircraft
N521VA
Make and model
Airbus A319112
Aircraft serial
2773
Part
Duct
Condition
Contaminated
Location
Cabin
Stage of operation
TX
How discovered
O
Nature of condition
B
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SMOKE IN CABIN AND COCKPIT. VERBAL TURNOVER FROM CREW. SMOKE APPEARED AFTER LANDING AND EXITING RUNWAY. RAN APU, OPERATED PACKS, FOG APPEARED BRIEFLY, FOG CLEARED, NO SMOKE, RAN NR 1 AND NR 2 ENGINES AT IDLE FOR 5 MINUTES. PER 71-00-00-710-006, CLEARED PNEUMATIC DUCTS OF MOISTURE, BELIEVE CONDITION OCCURS DUE TO SNOW REMOVAL, ENGINES PICKING UP MOISTURE, AIRCRAFT OK FOR SERVICE.

More about the Airbus A319-112