What was found
DURING C AND D BRIDGING AND ALIGNMENT CHECK INSPECTION, FOUND 6 INCH CRACK IN LONGERON 30 STATION 360 TO 366. REMOVED AND REPLACED LONGERON 30 STATION 360 TO 366 IAW DC9 SRM 51-01 AND 51-30-5. NON-ROUTINE WORK CARD NR 96-0196 AND 96-0264. REPORT GENERATED BY AMERICAN INTERNATIONAL AIRWAYS, INC B4MR FOR USA JET AIRLINES, Y2PA.