What was found
DURING C AND D BRIDGING AND ALIGNMENT CHECK INSPECTION, FOUND STATION 229 TO 280 LONGERON 28R CORRODED. REMOVED AND REPLACED LONGERON 28R STATION 229 TO 280 IAW DC9 SRM 51-01 AND 51-30-5. NON-ROUTINE WORK CARD NR 96-0196 AND 96-0249. REPORT GENERATED BY AMERICAN INTERNATIONAL AIRWAYS, INC B4MR FOR USA JET AIRLINES, Y2PA.