Service difficulty report · Filter · Emb ERJ190100IGW

Difficulty date
July 29, 2008
Submitted
August 6, 2008
Operation
Air carrier
Aircraft
N249JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000045
Aircraft time
5,544 hours, 3,392 cycles
Part
Filter
Condition
Contaminated
Location
A/C Pack
Stage of operation
NR
How discovered
O
Nature of condition
B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 907, JFK-ORD, AIR RETURN TO JFK, RECEIVED LAV SMOKE WARNING IN FLIGHT. LANDED ACFT ASAP, FOLLOWED QRH PROCEDURES. SMOKE WAS VISIBLE IN CABIN INITIALLY AND THEN DISSIPATED WITH TIME. LAV SMOKE WARNING WENT OUT AFTER SMOKE DISSIPATED. NO VISIBLE SMOKE IN COCKPIT. PERFORMED LTV SMOKE ODOR INSPECTION PER 44-20-10. INSPECTION WAS GENERAL TO CABIN, NO FAULTS NOTED. PERFORMED VISUAL INSPECTION OF NR1 AND NR2 PACK INLETS. FOUND EVIDENCE OF COFFEE RESIDUE ON NR 2 PACK INLET. SMALL TRACES OF COFFEE STAINS ON NR 2 PACK INLET. CLEANED RESIDUE FROM PACK INLET NR 2 AND REMOVED AND REPLACED RECIRC FAN AIR FILTERS AS PER MM 21-24-02. ACFT OK FOR SERVICE. (S)