What was found
ODOR FROM LTV OF ROW 20, WENT AWAY WHEN LTV SHUT OFF. PERFORMED INSP OF ALL LTV COMPONENTS AFT OF ROW 18 IAW JB INFO NOTICE 2003-T050TRA. FOUND SLIGHT ELECTRICAL ODOR ON SEB AT 26D. REMOVED AND REPLACED SEB AT SEAT 26D IAW AMM 23-39-00, SYSTEM OPS CHECK NORMAL.