What was found
LIVE TV SYS INOP. DUE TO BURNING ODOR AT 7D, PERFORMED LIVE TV SYSTEM INTEGRITY CHECK CONCERNING ELECTRICAL ODOR & INFORMATION NOTICE 2003-T050TR A. FOUND DISCOLORATION AT RJM (REMOTE JACK MARDULE) AT 7D. REMOVED AND REPLACED RJM IAW LTV MM 23-39-00. ALSO REMOVED SEB AT 7E AS PRECAUTIONARY IAW INFO NOTICE 2003-T050TR A AND IAW LTV MM 23-39-00. LTV SYS REACTIVATED. OPS CHECK NORMAL.