SDR YENA200664

Service difficulty report · Bleed Valve · Airbus A320232

Difficulty date
August 17, 2006
Submitted
August 22, 2006
Operation
Air carrier
Aircraft
N505JB
Make and model
Airbus A320232
Aircraft serial
1173
Aircraft time
25,810 hours, 10,357 cycles
Part
Bleed Valve
Part number
6774E010000
Part serial
00680
Condition
Faulty
Location
Nr 2 Engine
Part time
25,244 hours, 9,993 cycles
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PRESSURE PROBLEM. PRESSURE UNCONTROLLABLE, DIVERTED TO CLT. ON LANDING AT GATE WITH DOOR OPEN SHOWS MINUS -900 & .4 PSI. PFR SHOWS HISTORY OF NR 2 ENG BLEED PRESSURE REG VALVE/SOLENOID SENSE LINE FAULT. REMOVED & REPLACED NR 2 ENG BLEED VALVE (4001 HA2) IAW MM 36-1152 DUE TO SUSPECT FLUCTUATING BLEED PRESSURE OPS & LEAK CHECK OK. PERFORMED CABIN PRESSURE CHECK IAW AMM 05-53-00. OPS CHECK OK.