What was found
FLT 471, BOS-SJC, APPROX 03:15Z, WX RADAR WENT OUT FOLLOWED BY A ELECTRICAL BURNING SMELL. PULLED CB K13. CARRIED OUT INSP ON THE FWD AVIONICS BAY, FOUND WEATHER RADAR UNIT SMELLS BURNED, INSPECTED CONNECTORS, CHECKED GOOD. REMOVED AND REPLACED WX RADAR UNIT PER AMM 34-41-33, OPS TEST GOOD PER AMM 34-41-00-05. CARRIED OUT ELECTRICAL BURNING INSPECTION PER TSM 24-00-00-810-825.