As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLIGHT ATTENDANT REPORTED ELECTRICAL ODOR IN CABIN NEAR ROW 7. ODOR DISSIPATED AFTER APPROXIMATELY 30 MINUTES. COMPLIED WITH TSM 24-00-00-810-823. NO DEFECTS NOTED. PERFORMED INSPECTION OF LTV SYSTEM PER TSM 23-39-00-810-801. RAN SYSTEM FOR 2 HOURS WITH NO INDICATION OF ANY ODOR. REMOVED AND REPLACED VDU'S AND XEB'S IN ROW 7 AS PRECAUTIONARY PER TSM 23-39-00-810-801. OPERATION NORMAL PER AMM 23-39-00.