Service difficulty report · Shutoff Valve · Emb ERJ190100IGW

Difficulty date
April 8, 2008
Submitted
April 10, 2008
Operation
Air carrier
Aircraft
N238JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000039
Aircraft time
5,076 hours, 3,223 cycles
Part
Shutoff Valve
Part number
10012463
Part serial
2005060627
Condition
Failed
Location
Bleed System
Part time
5,601 hours, 3,544 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 1060, AUS-JFK, DIVERTED TO MCO, BLEED 2 FAIL EICAS MESSAGE AT 4000 FT, PERFORMED QRH AND PROBLEM RESOLVED. BLEED 2 FAIL MESSAGE RETURNED AT 14000 AND PERFORMED QRH, PROBLEM RESOLVED BUT RETURNED AND DESCENT INITIATED. PSI FLUCTUATION OF <10 TO >70. REMOVED AND REPLACED NR 2 BLEED NAC PRSOV, REF AMM 36-1-03, ITEM 2, OPS CHECK OK.