What was found
FLT 180, PHX-JFK, CRUISING AT 37,000, BLEED 2 THEN BLEED 1 FAULTED (BLEED AIR SUPPLY SYSTEMS). REMOVED AND REPLACED NR 1 ENG BLEED AIR SUPPLY SYS THERMOSTAT IAW 36-11-43-04, LEAK CHECK & OPS CHECKS OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLT 180, PHX-JFK, CRUISING AT 37,000, BLEED 2 THEN BLEED 1 FAULTED (BLEED AIR SUPPLY SYSTEMS). REMOVED AND REPLACED NR 1 ENG BLEED AIR SUPPLY SYS THERMOSTAT IAW 36-11-43-04, LEAK CHECK & OPS CHECKS OK.