As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLT 150 - MCO-JFK - ENG 1 SYSTEM FAULT ECAM WITH ASSOCIATED ENG 1 OVERTEMP ON DEPT AT 400 FT AGL UNABLE TO STABILIZE ENGINE, RETURNED TO MCO. PARAMETERS GIVEN TO LOCAL MAINTENANCE. REPLACED 10TH STAGE BLEED VALVE, 7TH STAGE SOLENOID VALVE PER TSM 73-00-00-810-837 AND 73-00-00-810-817. REMOVED AND REPLACED NR 1 ENG EEC IAW 73-22-34. PERFORMED ENGINE HIGH POWER ASSURANCE TEST, NO FAULTS NOTED. OPS CHECK GOOD.