Service difficulty report · Warning System · Emb ERJ190100IGW

Difficulty date
October 9, 2010
Submitted
October 11, 2010
Operation
Air carrier
Aircraft
N184JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000008
Aircraft time
13,472 hours, 8,274 cycles
Part
Warning System
Condition
False Activation
Location
Bleed Air Sys
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 590 PBI-HPN, FLT CREW DECLARED EMERGENCY AND A/C DIVERTED TO MCO DUE TO BLEED 2 LEAK MSG IN FL 310. QRH PROCEDURE COMPLETED. BLEED 2 SELECTED OFF (XBLEED) CAS MSG EXTINGUISHED. INTERROGATED CMC FOUND BLEED 2 LEAK, ODS PACK LOOP 5 (RT BLD) [C1] /WRG FAULT. T/S REF FIM 36-21-00-810-802-A AND 36-21-00-810-804-A00. CMC ODS PARAMETERS CONFIRM OVERHEAT COND TRUE, EVENT LOC 11.90 AND SHORT COND TRUE FOR SYS 2 BLEED CHAN 1 AND CHAN 2. PERF BLD ODS NVM READ/RESET MSG CLEARED/ FAULT CLEARED. REMOVED ACCESS PANEL 429AT PER FIM 36-21-00. PERF VISUAL INSP OF BLEED DUCTS, CLAMPS, LINES AND THERMAL INSUL REF AMM 36-11-04. NO DEFECTS NOTED AT THIS TIME. RAN ENG AND ENG BLEED. CONFIRMED NO PHYSICAL INDICATION OF BLEED LEAK NOTED. RE-INSTALLED ACCESS PANEL 429AT REF AMM 54-50-21. RESTORED A/C TO INITIAL CONFIG. A/C OK FOR CONT SERVICE.