What was found
FLT 590 PBI-HPN, FLT CREW DECLARED EMERGENCY AND A/C DIVERTED TO MCO DUE TO BLEED 2 LEAK MSG IN FL 310. QRH PROCEDURE COMPLETED. BLEED 2 SELECTED OFF (XBLEED) CAS MSG EXTINGUISHED. INTERROGATED CMC FOUND BLEED 2 LEAK, ODS PACK LOOP 5 (RT BLD) [C1] /WRG FAULT. T/S REF FIM 36-21-00-810-802-A AND 36-21-00-810-804-A00. CMC ODS PARAMETERS CONFIRM OVERHEAT COND TRUE, EVENT LOC 11.90 AND SHORT COND TRUE FOR SYS 2 BLEED CHAN 1 AND CHAN 2. PERF BLD ODS NVM READ/RESET MSG CLEARED/ FAULT CLEARED. REMOVED ACCESS PANEL 429AT PER FIM 36-21-00. PERF VISUAL INSP OF BLEED DUCTS, CLAMPS, LINES AND THERMAL INSUL REF AMM 36-11-04. NO DEFECTS NOTED AT THIS TIME. RAN ENG AND ENG BLEED. CONFIRMED NO PHYSICAL INDICATION OF BLEED LEAK NOTED. RE-INSTALLED ACCESS PANEL 429AT REF AMM 54-50-21. RESTORED A/C TO INITIAL CONFIG. A/C OK FOR CONT SERVICE.