As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLT 407 BOS-PHX, AFTER T/O CREW NOTICED AN ODOR AND CAPT'S CSS MONITOR WENT OFF. SUSPECTED A SHORT MAY HAVE CAUSED THE ODOR. SHUT DOWN SYSTEM TOGGLED SWITCHED AND VDU PWR CB. ODOR SUBSIDED (CABIN SURVEILLANCE SYSTEM -INOP. REMOVED AND REPLACED CSS CAPT VDU. OPS CHECK NORMAL IAW LTV MM 23-39-00.