What was found
FLT 1061 JFK-AUS, AIR RETURN TO JFK DUE TO HYD B ELEC PUMP OVHT ECAM ON CLIMBOUT. MESSAGE DID NOT CLEAR EVEN AFTER SHUTDOWN. TECHNICIAN REMOVED AND REPLACED HYD B ELECTRIC PUMP. OPS AND LEAK CHECK OK PER AMM 29-12-51-000-001.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLT 1061 JFK-AUS, AIR RETURN TO JFK DUE TO HYD B ELEC PUMP OVHT ECAM ON CLIMBOUT. MESSAGE DID NOT CLEAR EVEN AFTER SHUTDOWN. TECHNICIAN REMOVED AND REPLACED HYD B ELECTRIC PUMP. OPS AND LEAK CHECK OK PER AMM 29-12-51-000-001.