Service difficulty report · Shutoff Valve · Emb ERJ190100IGW

Difficulty date
July 25, 2011
Submitted
July 26, 2011
Operation
Air carrier
Aircraft
N294JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000185
Aircraft time
9,147 hours, 5,296 cycles
Part
Shutoff Valve
Part number
10012463
Part serial
200402298
Condition
Stuck
Location
Bleed Air Sys
Part time
6,146 hours, 3,545 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 335 IAD-MCO, UPON DEP AT 1500 AGL - REQ'D BLEED 1 OVERPRESS EICAS WHILE RUNNING QRH. BLEED 2 IS FLUCTUATING FROM 2-98 PSI WITH BLEED 1 ALREADY ON MEL, ELECTED TO RETURN TO AIRPORT. NO OTHER EICAS MESSAGES REC'D. INSPECTED AND FOUND NR 1 NAPRSOV STUCK IN THE OPEN POSITION. REMOVED AND REPLACED NR 1 NAPRSOV IAW 36-11-03. PERFORMED HIGH POWER RUN, PERFORMED OPS CHECK OF BOTH BLEED SYSTEM IAW 36-11-00. OPS CHECK GOOD NO DEFECTS NOTED. NR 1 AND NR 2 BLEED SYSTEM OPERATING NORMAL. MDDR 118416 CLOSED.

More about the Emb ERJ 190-100 IGW