What was found
FLT 824 SDQ-JFK, AIRCRAFT DIVERTED TO SJU DUE TO OXYGEN APPEARS TO BE LEAKING, DEPARTED WITH 550 PSI AFTER 30 MIN OF FLIGHT O2 WAS 360 PSI AND DECREASING. RESET ALL MASK BEFORE DEPARTURE. SERVICED CREW O2 BOTTLE IAW AMM 12-14-35 AND PERFORMED FIM TASK 35-10-00-810-813. RESEATED CREW OXYGEN MASK. NO FURTHER LEAKS NOTED, CREW O2 NOW AT 1340 PSI.