Service difficulty report · Overheat Loop · Emb ERJ190100IGW

Difficulty date
April 3, 2012
Submitted
April 4, 2012
Operation
Air carrier
Aircraft
N238JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000039
Aircraft time
16,395 hours, 9,582 cycles
Part
Overheat Loop
Condition
Out Of Position
Location
Nr 2
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT 598, CREW DECLARED EMERGENCY AND DIVERTED, DUE TO BLEED 2 LEAK WITH BLEED 1 ALREADY ON MEL. TROUBLESHOT PER FIM 36-21-00-810-800A. CMC ODS EVENTS AT 29.08 SHORT CONDITION AND AT 17.25 INOP LOOP AT NR 2 PYLON AND RT WING ROOT. FOUND 3 GROMMETS OUT OF PLACE. LOOP RUBBING ON CLAMP. REPLACED CLAMPS AT LOCATIONS. LOOP AT WING ROOT FOR LOCATION 29.0 LOOP LAYING IN CONTACT WITH DUCT. REALIGNED AS REQUIRED. RESET NVM OF ODS NR 1 AND NR 2. ASSURANCE RUN ACCOMPLISHED. NO FAULT AT THIS TIME.