What was found
FLT 1230 RDU-BOS, F/A REPORTS SMOKE SMELL IN CABIN AT 10,000 FEET. PACK 2 FAILED ON LANDING FIM TASK 21-51-00-810-A FOR SMELL OF SMOKE IN CABIN WITH ASSOCIATED PACK 2 FAIL EICAS MSG VERIFIED ACM 2 FAILED ITEM TRANSFERRED TO MEL 21-51-00 COND 1. OPS CHECK OF ELECT EQUIP RACK VENTILATION SHUTOFF VALVE, OPS NORMAL PER AMM 21-28-00-710-810A. REMOVED AND REPLACED ACM PER AMM 21-51-00. OPS CHECK GOOD.