Service difficulty report · Warning System · Emb ERJ190100IGW

Difficulty date
August 25, 2012
Submitted
August 27, 2012
Operation
Air carrier
Aircraft
N316JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000292
Aircraft time
9,463 hours, 5,716 cycles
Part
Warning System
Condition
False Activation
Location
Bleed Air Sys
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 3 BUF-JFK, CREW DECLARED EMERGENCY DUE TO BLEED 1 LEAK ILLUMINATED AFTER BRIEFLY ENCOUNTERING ICING CONDITIONS. NOTE : BLEED 2 WAS ALREADY ON MEL. QRH COMPLETED. PERFORMED FIM 36-21-00-810-801-A. FOUND EVENT LOCATION 15.40 CHANNEL 2 11.3 CHANNEL 1. PERFORMED NVM RESET ALL EVENT LOCATION CLEARED. PERFORMED OPS CHECK OF NR 1 BLEED SYS. OPS CHECK OK NO FAULTS NOTED.