Service difficulty report · Pressure Sensor · Emb ERJ190100IGW

Difficulty date
January 10, 2013
Submitted
January 11, 2013
Operation
Air carrier
Aircraft
N294JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000185
Aircraft time
13,292 hours, 7,843 cycles
Part
Pressure Sensor
Part number
10023911
Part serial
D11032064
Condition
Failed
Location
Bleed Air Sys
Part time
4,146 hours, 2,547 cycles
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 663 SYR-MCO, AIRCRAFT DIVERTED TO IAD DUE TO NR 1 ENGINE BLEED OVER PRESSURE MESSAGE AT 129 PSI. UNABLE TO RESET PER THE QRH. REFERENCE FIM 36-14-00-810-804-A, REMOVED AND REPLACED LEFT BLEED PRESSURE SENSOR REF AMM 36-14-02. BLEED FAIL CLEARED.