Service difficulty report · Wire Harness · Emb ERJ190100IGW

Difficulty date
January 12, 2013
Submitted
January 14, 2013
Operation
Air carrier
Aircraft
N329JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000433
Aircraft time
5,078 hours, 3,169 cycles
Part
Wire Harness
Condition
Defective
Location
Anti-Ice System
Stage of operation
CR
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 522 MCO-EWR, AIRCRAFT DIVERTED TO CLT DUE TO ANTI ICE WING 2 LEAK EICAS MESSAGE CAME ON AT FL370. NON ICING CONDITIONS SHUT OFF WING ICE DETECT BUTTON PER QRH MESSAGE EXTINGUISHED AND THEN RETURNED. SHUT BLEED 2 AND X BLEED PER QRH. MESSAGE RETURNED AND EXTINGUISHED. REMOVED AND REPLACED W611 HARNESS & TEMP SENSOR FOR NR 2 RIGHT SLAT OUTBOARD IAW AMM 30-11-02.