Service difficulty report · Bleed Valve · Emb ERJ190100IGW

Difficulty date
January 31, 2013
Submitted
February 1, 2013
Operation
Air carrier
Aircraft
N266JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000054
Aircraft time
17,217 hours, 10,290 cycles
Part
Bleed Valve
Part number
10012463
Part serial
2006090344
Condition
Failed
Location
Bleed Air Sys
Part time
17,232 hours, 10,291 cycles
Stage of operation
TO
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT NR 1731 JFK-BDA, AIR TURNBACK TO JFK DUE TO BLEED 1 AND 2 FAILED ON TAKEOFF AT TO-1. RESET SUCCESSFUL REPEAT AT 11000F. FAILED AGAIN BLEEDS 1 AND 2. REMOVED AND REPLACED ENGINE NR 1 PRSOV AS PER AMM 36-11-03. REMOVED AND REPLACED HP BLEED VALVE NR 2 AS PER 36-11-01 AND AMS CONTROLLER IN SPDA NR 2 SLOT 23 IAW 21-00-02 OPS CHECK NORMAL.