What was found
DIVERTED, DURING CLIMBOUT OF 19,000 FT POSSIBLE LIGHTNING STRIKE. MULTIPLE ELECTRICAL FAILURES. GEN NR 1, ALL EFIS DISPLAYES WENT BLANK. F/O'S CAME BACK FOLLOWED BY CAPTAINS, 1 MINUTE LATER. LIGHTNING STRIKE INSP, PERFORMED IAW AMM 05-51-200-001-A, NO STRIKES NOTED. R & R NR 1 ENGINE IDG IAW AMM 24-21-51-400, OPS CHECK & LEAK CHECK WERE NORMAL.