Service difficulty report · Warning Light · Emb ERJ190100IGW

Difficulty date
July 8, 2013
Submitted
July 9, 2013
Operation
Air carrier
Aircraft
N206JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000025
Aircraft time
20,288 hours, 12,534 cycles
Part
Warning Light
Condition
Illuminated
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW DECLARED AN EMERGENCY. AFTER LEVEL OFF AT 280 AVNX MAU 3A FAIL WITH ASSOCIATED ADS 3A SPOILER AND FDR AFT FAIL. RELATED FAULT MESSAGE 452147CMC AND PROCEEDED WITH RELATED FIM 31-42-00-810-812-A. RESET NIC PROC 5 ALL MESSAGE CLEARED. MCC VERFIED NO 30 DAY HISTORY. NO FURTHER ACTION REQUIRED AT THIS TIME.