Service difficulty report · Warning Message · Emb ERJ190100IGW

Difficulty date
December 29, 2013
Submitted
December 30, 2013
Operation
Air carrier
Aircraft
N316JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000292
Aircraft time
12,977 hours, 7,911 cycles
Part
Warning Message
Condition
Illuminated
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW INITIATED AN EMERGENCY DESCENT, DECLARED AN EMERGENCY AND ACFT DIVERTED, BLEED 2 LEAK CAS MESSAGE PASSING 28K. CONDUCTED QRH BLEED LEAK MESSAGE EXTIGUISHED AFTER BLEED 2 SELECTED OFF. TROUBLESHOT IAW FIM 36-21-00-810-802-A00 FOUND ERRONEOUS EVENT LOCATIONS ON SYS 2, CHANNEL B INSPECTED RT ODS LOOP 5. REPLACED CERAMIC PINS AT P 46, P1065, J2148, J1059. INSPECTED RT BLEED DUCTING FROM PYLON TO PACK BAY FOR EVIDENCE OF LEAKAGE NEAR LOOP 5 NO DEFECTS NOTED. FOUND RT PRECOOLER SEAL DETACHED FROM PYLON. SEALED IAW 36-11-08, OPS CHECK OF ENG BLEED IAW 36-11-00-710-801A GOOD.