What was found
DURING MAINTENANCE CHECK, FOUND CORROSION ON RT SEAT TRACK FR15 TO FR16, PN 170-03264-001. ACCOMPLISHED HFEC INSPECTION, CUTOUT AREA WITH .038" REMOVED, FABRICATED DOUBLER, DRILLED AND INSTALLED ALODINED, PRIMED AND TOPCOATED. WORK ACCOMPLISHED IAW EA E14-105-01.