As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CLIMBING THRU 3000' RECEIVED AN ECAM CAUTION ANTI-ICE CAPT LT STAT WITH AN ASSOICIATED ELECTRICAL OVERHEAT ODOR. SWITCHED TO ADR CAPT 3 IAW ECAM & ODOR QUICKLY DISSIPATED. FOUND ON PFR PHC NR 1 FAULTING, ON GROUND SCAN PH1 POWER SUPPLY. R & R PHC 1 IAW AMM 30-31-01. NO FAULTS NOTED. TEST OK.