What was found
DURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED AT FORWARD GALLEY TRACK AT FRAME 16, LBL 11.75". ACCOMPLISH DVI TO ENSURE ALL CORROSION IS REMOVED. FABRICATED REPAIR STRAP, APPLIED A COAT OF INTERFACE SEALANT. TREAT THE REPAIR PARTS WITH A PROTECTIVE FINISH. FILLED ANY REWORKED AREAS AS REQUIRED. TREATED, TOP COATED NEW DOUBLER, IAW E14-455-01 AND SRM 53-10-10, FIGURE 56A, ITEM 260.