What was found
DURING HEAVY MAINTENANCE, FOUND FLOORBEAM CORRODED AT FRAME 17 BETWEEN LBL 12 AND RBL 12. BLENDED OUT THE CORROSION IAW SRM 51-10-03 PART 11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE, FOUND FLOORBEAM CORRODED AT FRAME 17 BETWEEN LBL 12 AND RBL 12. BLENDED OUT THE CORROSION IAW SRM 51-10-03 PART 11.