What was found
DURING MAINTENANCE, EPSU FWD LT 10WL FOUND INOPERATIVE DURING EMERGENCY LIGHT TEST. R & R LT SIDE FWD EPSU IAW AMM 33-51-38. OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING MAINTENANCE, EPSU FWD LT 10WL FOUND INOPERATIVE DURING EMERGENCY LIGHT TEST. R & R LT SIDE FWD EPSU IAW AMM 33-51-38. OPS CHECKED GOOD.