Service difficulty report · Pressure Switch · Emb ERJ190100IGW

Difficulty date
March 27, 2015
Submitted
March 31, 2015
Operation
Air carrier
Aircraft
N258JB
Make and model
Emb ERJ190100IGW
Aircraft serial
19000047
Aircraft time
24,580 hours, 15,014 cycles
Part
Pressure Switch
Condition
Malfunctioned
Location
Nr 1 Bleed Sys
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIR RETURN DUE TO BLEED 1 OVER PRESSURE. COULD NOT RESET VIA QRH. CMC FAULT CODE 36146225AM1. PERFORMED FIM TASK 36-14-00-810-817-A. FAILURE OF THE OVER PRESSURE SWITCH. R & R 1 BLEED OVER PRESSURE SWITCH IAW AMM 36-14-01-000-801-A & 36-14-01-400-801-A. OPS CHECK GOOD.

More about the Emb ERJ 190-100 IGW