What was found
DURING HEAVY MAINTENANCE, DURING THE ACCOMPLISHMENT OF THE RUDDER SIDESHELL INSPECTION WATER INGRESSION FOUND AT HOIST POINT NR 3 IAW A320-55-1041-3. DURING PULSE INFARED INSPECTION, FOUND 1 AREA ON THE RT SIDE OF THE RUDDER SIDESHELL THAT IS OUT OF LIMITS IAW SRM A320-55-1041. SUBTASK 55-1041-832-204-001, ITEM 9. PERMANENT REPAIR WAS COMPLETED IAW EC A15-390-01 AND IN CONJUNCTION WITH E/A PT20-55-002. THIS TASK HAS BEEN CLASSIFIED AS A MAJOR REPAIR.