As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING HEAVY MAINTENANCE CORROSION WAS FOUND AT SHEAR CLIP FRAME 88 BETWEEN STRINGER 27R AND 28R. R & R FRAME 88 SHEAR CLIP BETWEEN STRINGER 27R AND 28R. REF EMB 190 SRM 51-41-01;51-41-02. TOP COATED REF 51-23-06. TOP COATED RIVETS AND HI LOCKS ON RT SHEAR PANEL AT FRAME 87 TO 88, REF SRM 51-23-06. THIS ITEM HAS BEEN CLASSIFIED AS A LEVEL 2 CORROSION.