What was found
ON HEAVY MAINTENANCE CHECK, FOUND AFT CARGO DOORWAY FWD END FINGER DOUBLER HAS CORROSION. BLENDED, REWORKED, CORROSION DAMAGE AND HFEC PERFORMED. REPLACED AFFECTED FASTENERS. APPLIED SURFACE PROTECTION TO REWORKED AREA. ALL WORK ACCOMPLISHED IAW EA E15-509-01.