What was found
DURING HEAVY MAINTENANCE, FOUND RT FLOOR SPLICE CORRODED FRAMES 18-19; RBL 12.5-RBL 29.5. REMOVED CORROSION, MAX MATERIAL LOSS IS L=3", W=3.5", H= 0.002". LOCATION IS 1.5" AFT OF FRAME 18, RBL 24" REF SRM 51-10-03;51-12-01. TREATED, PRIMED AND TOP COATED REF SRM 51-23-04; 51-23-05;51-23-06. THIS ITEM HAS BEEN CLASSIFIED AS A LEVEL 2 CORROSION.