What was found
DURING HEAVY MAINTENANCE, FOUND RT FLOOR SUPPORT IS CORRODED FROM FRAME 12-FRAME 14, RBL 36-49. REMOVED CORROSION, MAX MATERIAL LOSSES ARE: AREA A L=1.75, W=11.5, H= 0.002, LOCATION IS AT FRAME 14, RBL 38-49. REF SRM 51-10-03, TYPE D, BLEND OUT REF 51-12-01, 51-23-02. TREATED, PRIMED AND TOP COATED AREAS REF SRM 51-23-04, 51-23-05, 51-23-06.