What was found
DURING HEAVY MAINTENANCE, FOUND CORRODED SHEAR CLIP AT FRAME 17 BETWEEN STR 27R & 28R. REMOVED FABRICATED AND INSTALLED SHEAR CLIP AT FRAME 17 BETWEEN 27R & 28R, REF SRM 51-41-01 & 51-41-02. ALODINED, PRIMED AND TOP COATED, REF SRM 51-23-04, 51-23-05 & 51-23-06. THIS ITEM HAS BEEN CLASSIFIED AS A LEVEL 2 CORROSION.