What was found
DURING HEAVY MAINTENANCE, FOUND CORRODED SHEAR CLIP AT FRAME 16 BETWEEN STR 27R & 28R INSTALLED NEW SHEAR CLIP AT FRAME 16 BETWEEN STR 27R & 28R. REF SRM 51-41-01 & 51-41-02. PAINTED TOP COAT REF SRM 51-23-06, THIS ITEM HAS BEEN CLASSIFIED AS A LEVEL 2 CORROSION.