What was found
DURING HEAVY MAINTENANCE, FOUND AFT CARGO BAY FLOOR SHEAR CLIP CORRODED AT FRAME 82 BETWEEN STR 28L & 27L. REMOVED SHEAR CLIP FRAME 82 BETWEEN STR 28L & 27L. FABRICATED NEW SHEAR CLIP, COMPLIED WITH FPI INSPECTION, DRILLED, ALODINED, PRIMED AND TOP COATED AND INSTALLED FABRICATED SHEAR CLIP, SRM 51-43-03, SRM 51-41-01, SRM 51-41-02 NTM 51-00-00-9185-801A, SRM 51-41-01, SRM 51-41-02, SRM 51-43-03, SRM 51-23-04, SRM 51-23-05 AND SRM 51-23-06.