What was found
DURING HEAVY MAINTENANCE, FOUND FWD WET AREA -1292 CORRODED AT FRAME 20. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 51-74-00. R & R FLOORBEAM IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE, FOUND FWD WET AREA -1292 CORRODED AT FRAME 20. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 51-74-00. R & R FLOORBEAM IAW SRM 51-42-11.