What was found
DURING HEAVY MAINTENANCE FOUND CORROSION SHEAR TIE AT FRAME 17, STR 24-25R. REMOVED CORROSION AND FOUND THE SHEAR TIE TO BE OUT OF LIMITS. REMOVED THE SHEAR TIE , DRILLED A NEW SHEAR TIE AND INSTALLED IAW SRM 51-41-01, 51-41-02 AND 51-23-06.