What was found
DURING HEAVY MAINTENANCE, FOUND FWD CARGO DOOR BEAM CORRODED 8.25-9.25 INCHES AFT OF FRAME 26, RBL 15. R & R FORWARD CARGO DOOR CUTOUT LOWER BEAM IAW SRM 51-43-03 AND 51-53-04.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE, FOUND FWD CARGO DOOR BEAM CORRODED 8.25-9.25 INCHES AFT OF FRAME 26, RBL 15. R & R FORWARD CARGO DOOR CUTOUT LOWER BEAM IAW SRM 51-43-03 AND 51-53-04.