What was found
DURING HEAVY MAINTENANCE, FOUND AFT FLOOR SUPPORT WET AREA Y765 CORRODED AT FRAMES 66 TO 69. R & R NEW FLOOR SUPPORT AFT WET AREA AT Y765 AT FRAMES 64 TO 70 IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE, FOUND AFT FLOOR SUPPORT WET AREA Y765 CORRODED AT FRAMES 66 TO 69. R & R NEW FLOOR SUPPORT AFT WET AREA AT Y765 AT FRAMES 64 TO 70 IAW SRM 51-42-11.