What was found
DURING HEAVY MAINTENANCE, FOUND AFT WET AREA SUPPORT Y-765 CORRODED FRAME 66-69. R & R NEW FLOORBEAM AFT WET AREA Y-765 FRAME 64-70 IAW SRM 51-42-11. THIS ITEM HAS BEEN CLASSIFIED AS A LEVEL 2 CORROSION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE, FOUND AFT WET AREA SUPPORT Y-765 CORRODED FRAME 66-69. R & R NEW FLOORBEAM AFT WET AREA Y-765 FRAME 64-70 IAW SRM 51-42-11. THIS ITEM HAS BEEN CLASSIFIED AS A LEVEL 2 CORROSION.