What was found
DURING HEAVY MAINTENANCE FOUND LT AFT OTBD FLOORBEAM L2 DOOR CORRODED. REPLACED FLOORBEAM Y1292 IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE FOUND LT AFT OTBD FLOORBEAM L2 DOOR CORRODED. REPLACED FLOORBEAM Y1292 IAW SRM 51-42-11.