What was found
AFT CABIN FLOORBEAM -Y1292 CENTER TRIPLE BEAM CORRODED AT SPLICE STR 23R 9" FWD FRAME 68; R & R AFT CABIN FLOORBEAM -1292, STR 23R IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CABIN FLOORBEAM -Y1292 CENTER TRIPLE BEAM CORRODED AT SPLICE STR 23R 9" FWD FRAME 68; R & R AFT CABIN FLOORBEAM -1292, STR 23R IAW SRM 51-42-11.