What was found
CORROSION WAS FOUND ON FLOOR SUPPORT AT FRAMES 64-67, RBL 512. REMOVED CORROSION IAW SRM 51-22-00. R & R FLOOR SUPPORT IAW 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION WAS FOUND ON FLOOR SUPPORT AT FRAMES 64-67, RBL 512. REMOVED CORROSION IAW SRM 51-22-00. R & R FLOOR SUPPORT IAW 51-72-11.